Complément alimentaire pour favoriser la relaxation et le bien-être physique et mental. Valériane ipowder®, aubépine, L-tryptophane, vitamines B1, B3, B6, B8, B9, B12, magnésium et cuivre. Etui de 2 blisters de 15 comprimés format amande sécables avec pelliculage naturel garanti sans dioxyde de titane. La valériane est issue de la technologie ipowder®, un procédé d'extraction permettant d'obtenir des infusés végétaux concentrés garantis sans solvant et sans ajout de support. La valériane est traditionnellement utilisée pour favoriser la relaxation et le bien-être physique et mental. Les vitamines B1, B3, B6, B8, B9, B12 et le magnésium contribuent à des fonctions psychologiques normales. Le cuivre contribue au fonctionnement normal du système nerveux.
Stropna požarna vrata EI 60 - požarna past

Stropna požarna vrata EI 60 - požarna past

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboard Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018EN 1634-1: +A1: 2018 Fire dampers EI 60 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.
Stropna požarna vrata 120 MN - požarna past

Stropna požarna vrata 120 MN - požarna past

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018 Fire dampers EI 120 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 120. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.
Stropna požarna vrata 60 MIN - požarna vrata

Stropna požarna vrata 60 MIN - požarna vrata

Frame made of aluminium profile bars connected by "Tox" connections - Intumescent gas, smoke and flame tight seal in case of fire - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards - Quick and easy installation The 60-minute ceiling fire dampers are designed for installation in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60. They provide effective protection against fire progression from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms. The safety catching arms ensure that the lid is intercepted every time the hatch is opened. The lid is easy to remove and replace.